Cell Based Proces
- Carbonators are broken down and follow component specific testing process
- Tanks are pressure tested and examined for leaks
- Motors and probes are tested for communication
- Procon pumps are individually tested for flow rate and cycle time
- Backflow preventer repair kits proactively replaced on every carbonator
- Tanks and base plates are hand detailed and cleaned
- Motors are cleaned and painted
- All units are re-assembled and hi-pot tested prior to functionality testing
- Units are checked for flow rate, cycle time, and amp draw
- Safety relief valve is checked for functionality
- Units are visually inspected for cleanliness and hi-pot tested again before final packaging
Drop Off or Ship All Soda Valves, Carbonators, BIB Pumps, Regulators, Barguns and Dispensers to:
SODA PARTS EXPRESS GEKAY
3285 Intermodal Drive (last garage door, back of building)
Winter Haven, Florida 33880 Attention; Ty Norman